SUNNY ROO INVERTER WARRANTY
So a few years ago you thought you would put a solar power system on your home and you thought that getting the cheapest quote possible was the way to go, so off you went and went with the cheapest quote that sat on your on the kitchen table, the beyond building energy quote. Well, didn’t that turn out to you bite you on the bum?

Beyond Building Energy – Sunny Roo inverter
So along came beyond building energy, a few weeks later and installed your system complete with a sunny roo inverter. You had now been sunny rooted!
Let me clarify what it means by saying that you have been sunny rooted – your sunny roo inverter now no longer has a warranty. It’s a boat anchor, and probably a very good one at that. Your SR 5000TL is dead!
Replacement and Repair – Sunny Roo Inverter Warranty
This inverter was doomed from the beginning, a terrible inverter with a solar installation company who had entire interest in the inverter, and also the warranty with that. Beyond building Energy actually owned sunny roo inverters.
So you’ve stumbled across this page in search of sunny roo inverter warranty. Well, I’m going to now tell you that no such sunny roo inverter warranty exists, the sunny roo inverter warranty disappeared the same time that the beyond building energy when out of business.
The good news is you have a solar sytem on your roof of your house now for at least three years and it’s been working well. Up until now.
The generous feed in tariffs that the government were dishing out back then and unbelievably cheap prices that beyond building energy were selling the solar systems for means that, all the more likely your system has well and truly paid for itself. Now that’s a good thing. DO NOT REPAIR YOUR SUNNY ROO inverter, you will continue to waste money!
Beyond Building energy receivership
The thing is that now you have a dead sunny roo inverter with no warranty, and this sunny roo inverter will need replacing. This is going to cost you money.
The good news is that Queensland solar lighting can replace your dead sunny roo inverter. We can replace it with a quality Chinese inverter inverter, such as a JFY inverter or perhaps this time around you want to do it the entire opposite way of how you first did it, and get the best inverter in the market, a German SMA inverter. Either way that this is done, you are surely going to end up with a better result than having beyond building energy go out of business on you and at the same time forfeit your inverter warranty.
Every week we get a few calls from beyond building energy customers calling us up and asking if we fix sunny roo inverters or if we have a suitable replacement inverter for them and their system.
We are always happy to help these customers who’ve been burnt in the past, we will show them how to operate their new and far superior inverter. We show them how to troubleshoot and identify any problems that may arise in the future.
We really want all our customers to feel that they really understand what a solar inverter is, what it can do further them, how to operate it, how it operates and why it is important that it is always working for them.

There are a few clever people around out there who are fixing the sunny roo inverters that have died. However, while these people can easily fix the inverters, the inverters are also prone to breaking again. Then you guessed it, under no warranty. This is the reason it is best just to replace the whole inverter, get a proper inverter and do it properly from the beginning.
Replacement inverter price list
if you need to replace your sunny roo inverter because it is faulty and not turning on, the below price list applies to you if you live in Brisbane or Gold Coast.
Inverters that we install come with a five year warranty minimum. These inverters warranty is backed by Queensland solar and lighting and also the solar inverter manufacturer’s warranty.
Please see below for the replacement inverter pricelist
INVERTER REPLACEMENT SUPPLY AND INSTALL
SIZE JFY SINGLE TRACKER JFY DUAL TRACKER SMA
1.5 KW $1100 — $1700
2.0 KW $1200 — $1980
3.0 KW $1400 $1590 $2295 (DUAL TRACKER)
4.0 KW $1500 $1600 $2460 (DUAL TRACKER)
5.0 KW $1600 $1700 $2700 (DUAL TRACKER)
THESE PRICES INC GST AND ARE BASED ON WITHIN 50KM RADIUS OF Logan OR Tweed heads
FOR JOBS OUTSIDE THE 50KM RADIUS TRAVEL WILL BE CHARGED AT $2.5 KM
Sunny Roo Solar Inverter Error Codes and Descriptions
LCD Indicate | Designation | Description | Repair |
Er00 | DC_BUS pre-Charge fail | The inverter is in soft start procedure, but the DC Bus cannot reach and maintain anticipative charging voltage | 1. Disconnet ALL PV (+) or PV (-) 2.Wait for a few seconds 3. After the LCD switches off, reconnect and check again 4. If error code keeps recurring, contact your local distributor |
Er03 | INVERTER voltage abnormal |
The inverter output voltage is abnormal |
|
Er07 | DC_BUS over-voltage | The DC BUS inside is lower or higher than expected | |
Er08 | DC_BUS under-voltage | ||
Er17 | EEPROM ERROR on the control board | EEPROM data is wrong | |
Er19 | DC_BUS discharge fail | Capacitors of the DC Bus can’t be discharged down | |
Er22 | Output relay fail | The Sunny Roo inverter output relay is abnormal | |
Er24 | Output current sense fail | The inverter output current fails to detect | |
Er25 | BOOSTER_A over-current | Over current on the DC side. This fault code is displayed if the current in the DC network is larger than specified. | |
Er26 | BOOSTER_B over-current | ||
Er30 | Rating setting of driver board does not match EEROM of control board | EEPROM data is wrong | |
Er06 | EPO | Inverter enters into EPO mode (Emerge Power Off) | 1. Remove the short circuit occurred at the EPO terminal 2. If error code keeps recurring, contact your local distributor. |
Er09 | Inverter output over-current | Over-current on the AC side. This fault code is displayed if the current in the AC network is larger than specified. | 1. Turn off AC breaker, then check the peripheral AC system configuration and the grid connections. 2. If error code keeps recurring, contact your local distributor. |
Er11 | Inverter over-load | Overload on the AC side. This fault code is displayed if the load on the AC network is larger than specified. | |
Er13 | INVERTER short circuit | Short circuit on the AC side | |
Er14 | INVERTER PLL fail | The phase of inverter can’t synchronise with the utility. | |
Er29 | INVERTER output DC current over spec. | The DC component of the electricity fed into the grid is longer than permissible range. | |
Er10 | Inverter over temperature | The internal temperature is too high. | 1. Try to reduce the ambient temperature. 2. Move the inverter to a cooler place. 3. If error code keeps recurring, contact your local distributor. |
Er18 | Heat sink over temperature | The heat sink temperature is too high. |
Sunny Roo Solar Inverter fault alarm codes and descriptions
LCD Indicate | Designation | Description | Repair |
AL00 | Utility voltage over-voltage | Utility voltage greater or smaller than the permissible value | 1. Wait for 1 minute, if the grid returns to normal, the Sunny Roo inverter automatically restarts. 2. Check grid connection, such as wires and connectors 3. Make sure grid voltage and frequency meet the proper specifications. 4. If error code keeps recurring, contact your local distributor for help. |
AL01 | Utility voltage under-voltage | ||
AL02 | Utility voltage over-frequency | Utility frequency greater or smaller than the permissible value. | |
AL03 | Utility voltage under-frequency | ||
AL04 | BOOSTER_A Input over-voltage | Over or under voltage at DC input | 1. Disconnect ALL PV (+) or PV (-). 2. Check the open PV voltage is outside the 120Vdc ~ 500Vdc 3. If PV voltage is normal and the problem still occurs, contact your local distributor for help. |
AL05 | BOOSTER_A Input under-voltage | ||
AL06 | BOOSTER_B Input over-voltage | ||
AL07 | BOOSTER_B Input under-voltage | ||
AL08 | Anti-Islanding | No utility or utility fail | 1. Disconnect ALL PV (+) or PV (-). 2. Check grid connection, such as wires and connectors. 3. Check grid usability. 4. If utility is normal and the error code keeps recurring, contact your local distributor for help. |
AL09 | Inverter voltage unbalance | Inverter voltage waveform is unbalanced | 1. Shutdown inverter (unplug PV generator from the input). 2. Check grid usability and restart the inverter (plug PV generator back into input). 3. If error code keeps recurring, contact your local distributor for help. |
AL10 | GFDI | Leakage current on ground conductor is too high. | 1. Unplug PV generator from the input, check AC peripheral system. 2. After the problem is cleared, re-plug the PV. Check the PV-inverter status. 3. If error code keeps recurring, contact your local distributor for help. |
AL11 | Isolation Fault | The impedence is between PV (+) & PV (-) and ground is lower than 2M Ohm. | 1. Disconnect ALL PV (+) or PV (-). 2. Check the impedence between PV (+) & PV (-) and ground. The impedence must be larger than 2M Ohm. 3. If error code keeps recurring, contact your local distributor for help. |
AL13 | Phase or utility fail | No utility or utility fail | 1. Disconnect ALL PV (+) or PV (-). 2. Check grid connection, such as wires and connectors. 3. Check grid usability. 4. If utility is normal and the error code keeps recurring, contact your local distributor for help. |
AL14 | Waveform of utility fail |
Below are also some pictures for you to download with the relevant error code.





Sunny roo inverter error codes
Thank you for reading our sunny roo inverter review and also our information about beyond building energy receivership.
I have a Sunnyroo 2000 inverter that has gone up to 9999kwh and then started displaying a strange reading. I U nderstand that this counter has to be reset to record readings in KWhs. Would someone be able to advise me on to reset the KWh counter on this inverter, please?
Thanks
Hi
Public knowledge to be spread because this asshole who was running the company beyond building Vince Smith who decided to close it’s door due to faulty products and taxes owed to ATO , also is owner of Watt test , this company is based in exactly the same address as Beyond building . Now what this company does is offer third party insurance lol , which advises people they are Nata accredited and so forth , they have people calling them unaware who they are to fix there inverters and this moron charges you for it . My point is that they charge you for the faulty inverters they supplied you in the first place so i would be spreading the word that beyond building ex director Vince Smith is behind Watt test do not trust them as far as u can throw them . He lives at 13 Queens Anne court Sovereign island, if you call watt test he will answer the phone as brian or Lee
I have been attempting to resolve same problem. Will advise if any results.
Hope all goes well!
I’ve had a Sunny Roo SRP3000TL for over 4 years. I don’t know if this has had anything to do with its longevity, but I had an Elko SOU-1 DIN rail sundown sensor installed between the mains power and the circuit breaker for the unit. (Hugomuller also make an equivalent “Paladin”). It turns on before the sun hits the solar array, and turns off about 15 minutes after the sunny Roo shuts down in the evening. The reason I had this installed is because the inverter was using about 150 watts per hour during the night, when it was supposed to be off.
I have also a Sunnyroo 2000 inverter that has gone up to 9999kwh and then started displaying a strange reading. I U nderstand that this counter has to be reset to record readings in KWhs. Would someone be able to advise me on to reset the KWh counter on this inverter, please?
please quote on replacement of 4.2 sunnyroo inverter. gold coast.